Electrical Specifications
TM-F2OP-C1XN-01 A-3
Drift (8 hours):
g
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
For Resistive Programming:
Voltage (0.3% of Vmax)
Current (0.3% of Imax)
3.75 mV
150 mA
22.5 mV
900 mA
6mV
110 mA
36 mV
660 mA
10 mV
65 mA
60 mV
390 mA
16.5 mV
42.5 mA
99 mV
255 mA
20 mV
35 mA
120 mV
210 mA
Temperature Coefficient:
h
Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)
For Resistive Programming:
Voltage (0.06% of Vmax/°C)
Current (0.06% of Imax/°C)
1.5 mV
90 mA
4.5 mV
180 mA
2.4 mV
66 mA
7.2 mV
132 mA
4mV
39 mA
12 mV
78 mA
6.6 mV
25.5 mA
19.8 mV
51 mA
8mV
21 mA
24 mV
42 mA
OVP Adjustment Range:
(5% to 110% of Vmax) 0.375-
8.25 V
0.6-13.2 V 1-22 V 1.65-
36.3 V
2-44 V
Efficiency:
i
0.80 0.82 0.85 0.85 0.87
a. Minimum output voltage is <0.15% of rated voltage at zero output setting.
b. Minimum output current is <0.5% of rated current at zero output setting when measured at minimum 10% of full power
load.
c. For input voltage variation over the AC input voltage range, with constant rated load.
d. For 0-100% load variation, with constant nominal line voltage.
e. Current mode noise is measured from 10% to 100% of rated output voltage, full current.
f. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
g. Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
h. Change in output per °C change in ambient temperature, with constant line and load.
i. Typical efficiency at nominal input voltage and full output power.
Table A-1
Specifications for 7.5 V to 40 V Models
Models 7.5-300 12-220 20-130 33-85 40-70

Table of Contents