Electrical Specifications
TM-F2OP-C1XN-01 A-5
Temperature Coefficient:
h
Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)
For Resistive Programming:
Voltage (0.06% of Vmax/°C)
Current (0.06% of Imax/°C)
12 mV
13.8 mA
36 mV
28 mA
20 mV
8.4 mA
60 mV
16.8 mA
30 mV
5.4 mA
90 mV
10.8 mA
60 mV
2.7 mA
180 mV
5.4 mA
120 mV
1.2 mA
360 mV
2.4 mA
OVP Adjustment Range:
(5% to 110% of Vmax) 3-66 V 5-110 V 7.5-165 V 15-330 V 30-660 V
Efficiency:
i
0.90 0.90 0.90 0.91 0.91
a. Minimum output voltage is <0.15% of rated voltage at zero output setting.
b. Minimum output current is <0.5% of rated current at zero output setting when measured at minimum 10% of full power
load.
c. For input voltage variation over the AC input voltage range, with constant rated load.
d. For 0-100% load variation, with constant nominal line voltage.
e. Current mode noise is measured from 10% to 100% of rated output voltage, full current.
f. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
g. Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
h. Change in output per °C change in ambient temperature, with constant line and load.
i. Typical efficiency at nominal input voltage and full output power.
Table A-2
Specifications for 60 V to 600 V Models
Models 60-46 100-28 150-18 300-9 600-4