Amprobe Europe GmbH AT-2000
- 22 -
SPECIFICATIONS
General
Operating Temperature: 0 to 120° F (-18°C to 49°C)
Storage Temperature: -40 to 150° F (-40°C to 66°C)
Case Material: ABS
Case Size: 11"x15"1/2" x 4" (39.4 x 27.9 x 10.2 cm)
R2000 Receiver
Detectors: Electromagnetic coil pickup for short mode.
Electrostatic plate pickup for open mode.
Sensitivity Selection: x1, x10, x100 course gain adjustment;
0-10 fine adjustment.
Short Mode performance: Over 20 feet in air under test conditions
Open Mode Performance: Over 12 feet in air under test conditions
60Hz Rejection: 120db
Power Source: 9V alkaline battery
Display: 10 LED's with chroma filter lens
Case: Flame retardant ABS 911
Weight: 6.2 oz (176grms)
S2300 Load Signal Generator
Operating Voltage: 9-300 volts AC or DC
Operating frequency: 32.768 KHz
Duty Cycle: Transmits 2 pulses with a duration of 0.0625 each every
0.5 seconds
Current Output-
Low Mode: 35mA peak, 4mA average
HIGH Mode: 70mA peak, 6mA average
Fuse: Fast acting 250mA @ 380V (6mm x 32mm)
Cat. No. 380.25-6x32
Case: Flame retardant ABS 911
Weight: 3.7 oz (105 grams)