SafeWizard Operating Instructions American Security Products Company
Last Revision 10/17/2008 Page 48 of 73 Document 4305199
Chapter 3-4-2-5
Factory Menus-
Locks & Doors-
Setup Deposit Lock
Setup Deposit Lock screen is used to configure the deposit lock feature of the SafeWizard.
3-4-2-5.1 Locks and Doors Menu
1 Set Safe Locks
2 Set Door Sensors
3 Set Entry Doors
4 Set Installed Doors
5 Setup Deposit Lock
QUIT back
Press 5, “Setup Deposit Lock”.
3-4-2-5.2 Locks and Doors Menu
Deposit Lk Enable N
Door Type B/W w/S
Activate Time 03
Open Time 020
Behind Door 00
Pres:0.09 Meas:0.00
Tolerance (in) 0.06
BACK-QUIT # sets pos
Setting up a deposit lock is a great deal like setting up any other
installed door on a SafeWizard. The first field determines whether or
not a sensor will be installed on this door. Activate Time
configures how much time you have to open the door. The
O
pen
Time is how long the door can be open before an alarm will sound.
The door sensor settings are configured by pressing the “#” key while
the door is closed.