Start up Guide for Axpert-VT240S Series AC Drive
27
C06
C04-D Pick up (Speed Search
Selection)
Enables “Catch-a-Spinning Load” Function. Related parameters
are C21-1 ~ C21-7
C09-0 Parameter protection Set to prevent unintentional parameter change from keypad
C09-1 Operation panel lock Set to prevent unintentional operation from keypad
C09-3 Reverse Direction Lock Prevents the motor from running in the reverse direction
C09-7 Default Value Load Multiple options to set the parameters to default condition
C11-0 Initial mode
Select initial operation mode (local or remote) when the power is
turned ON
C12-0 ~
C12-3
Parameter setting for
Analog Input AI1
These parameters select voltage or current type input, range
and filter time constant for AI1
C12-4 ~
C12-7
Parameter setting for
Analog Input AI2
These parameters select voltage or current type input, range
and filter time constant for AI2
C12-8 ~
C12-A
Parameter setting for
Analog Input AI3
These parameters select voltage or current type input, range
and filter time constant for AI3
C13-0 Analog output A01 Selects the function of the analog output 1
C13-1 Analog output A02 Selects the function of the analog output 2
C13-3 ~
C13-5
PSO 1 – 3 Selects the function of the Open Collector Outputs
C13-2 &
C13-6
Programmable Relays Selects the function of the Programmable Relays
C30-0 Control mode selection Selects the control mode and inverter duty.
U00-0 Parameter copy function Use this parameter to copy the parameters and paste into
another unit