Installing Wall-Mount (MXD) Panels
27
Modero S Series Touch Panels - Installation & Hardware Reference Manual
CAUTION:
The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM].
Excessive torque on the tab screws can strip out the locking tabs or damage the Backbox.
Extend the Locking Tabs only AFTER the Backbox is inserted into the wall.
When installing the Backbox, make sure that it is positioned correctly.
FIG. 21
MSD-1001-L Backbox - Locking tab and locking tab screws (X4)
FIG. 22 MSD-701-L Backbox - Locking tab and locking tab screws (X2)
FIG. 23 MSD-431-L Backbox - Locking tab and locking tab screws (X2)
Locking Tab screw (x4) - tighten to extend
each of the four Locking Tabs
(max torque = 5 IN-LB)
Locking Tab (x4)
10.1” Wall Mount Backbox
Locking Tab screw (x2) - tighten to extend
each of the four Locking Tabs
(max torque = 5 IN-LB)
Locking Tab (x2)
7” Wall Mount Backbox
Locking Tab screw (x2) - tighten to extend
each of the four Locking Tabs
(max torque = 5 IN-LB)
Locking Tab (x2)
4.3” Wall Mount Backbox