17
5.3 Command Details
The details of the device messages added by the Pattern Generator implementation are as follow:
: PATTern: STATe <Boolean>
Function ............ The Pattern Generator output ON/OFF is set.
Parameter .......... <Booleam> = ON or 1
OFF or 0
Unit ................... <Non term>
Restriction ......... None
: PATTern: STATe?
Function ............ The Pattern Generator output ON/OFF is inquired.
Response ........... The Pattern Generator status = OFF
ON
Restriction ......... None
: PATTern: SELect <Character>
Function ............ The Pattern Generator delivery data pattern is selected.
Parameter .......... <Character> = DEF1
DEF2
DEF3
DEF4
PN9
PN15
0101
Unit ................... <Non term>
Restriction ......... This cannot be set during the data pattern delivery.
: PATTern: SELect?
Function ............ The Pattern Generator delivery data pattern is inquired.
Response ........... The Pattern Generator delivery data pattern = DEF1
DEF2
DEF3
DEF4
PN9
PN15
0101
Restriction ......... None
5.3 Command Details