3-4 Commands Command Directory
3-60 PN: 10370-10374 Rev. F MG369xC GPIB PM
LSP
Description: Selects the power level sweep mode.
In Power Level Sweep mode, the power level will sweep as determined by the preset (or
previously set) dwell-time and number-of-steps parameters.
Functional
Category: POWER LEVELING
Related
Commands: LOG, LIN, PDT, PNS, PU0, PU1, PU2
Front Panel Key: Level | Level Sweep
LST
Description: Places the MG369xC in list sweep mode.
In list sweep mode, up to four lists of 2000 non-sequential frequency/power level sets can
be stored and accessed. A list index (0 through 1999) identifies each frequency/power
level set in a list. When commanded, the MG369xC generates a phase-locked step sweep
between the specified list start index and list stop index.
Functional
Category: LIST SWEEP
Related
Commands: ELI(xxxx), ELN(x), LF, LP, LIB(xxxx), LIE(xxxx), LEA
Front Panel Key: Frequency | List
LU0
Description: Turns off the active user level calibration table.
Functional
Category: USER LEVEL CAL
Front Panel Key: Level | User Lvl Cal | Off
LU1
Description: Activates user level calibration table #1.
Turns off any other active user level calibration table.
Functional
Category: USER LEVEL CAL
Front Panel Key: Level | User Lvl Cal | User 1 | On
LU2
Description: Activates user level calibration table #2.
Turns off any other active user level calibration table.
Functional
Category: USER LEVEL CAL
Front Panel Key: Level | User Lvl Cal | User 2 | On