EasyManua.ls Logo

Anritsu Site Master S113B - Page 6

Anritsu Site Master S113B
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Saving a Display to Memory ............................4-4
Recalling a Display From Memory ........................4-4
SWR (Return Loss) and Cable Loss Measurement ............4-6
Required Equipment ................................4-6
Device-Under-Test Specification..........................4-6
Procedure ......................................4-6
Selecting the Measurement Mode .........................4-6
Selecting the Frequency Range ..........................4-6
Performing a Calibration .............................4-7
SWR or Return Loss Measurement ........................4-8
Set the Amplitude Scale and Limit Line .....................4-8
Setting the Markers.................................4-9
Cable Loss Measurement ..........................4-10
Setting the Amplitude Scale ...........................4-10
Setting the Markers ................................4-11
DTF Measurement .............................4-12
Required Equipment ...............................4-12
Device-Under-Test Specification .........................4-12
Procedure .....................................4-12
Selecting the Measurement Mode ........................4-12
Performing a Calibration .............................4-13
DTF Measurement (Determining the Length of the Cable) ..........4-14
Setting the Amplitude Scale ...........................4-14
Setting the Marker ................................4-14
DTF Measurement (Determining the quality of the cable.) ..........4-16
Setting the Amplitude Scale ...........................4-16
Setting the Markers ................................4-16
Making Power Measurements .......................4-18
Entering Power Monitor Mode..........................4-18
Zeroing the Power Monitor............................4-18
Measuring High Input Power Levels.......................4-18
Displaying Power in dBm and Watts ......................4-18
Displaying Relative Power ............................4-18
Making a Measurement with the Spectrum Analyzer ..........4-19
Example Measuring a 900 MHz signal..................4-19
Set the Site Master to Spectrum Analyzer mode ................4-19
Set the center frequency .............................4-19
Set the frequency span ..............................4-20
Setting the marker.................................4-20
Set the Reference Level ..............................4-21
Chapter 5 - Software Tools Program 5-1
Description ..................................5-1
Requirements .................................5-1
Communication Port Setting.........................5-1
Changing COM Port Settings–Windows 95/98/NT ...............5-1
Software Installation .............................5-3
Plot Capture..................................5-3
Capture multiple traces to a database.......................5-4
Capture single or multiple traces to PC screen..................5-4
Program Operation..............................5-5
ii

Table of Contents

Related product manuals