E6 32 DTR.APC.APR.ALW.03(ENG)
5.3.4. APR-2000ALW, Metrological parameters
Accuracy ± 0.075% (FSO) of the calibrated range
± 0.1% (FSO) for range n°10
Special version ± 0.05% of the calibrated range
Long term stability accuracy / 3 years
or ≤ 2 x accuracy / 5 years
HS version ≤ accuracy for 6 years
Error due to supply voltage changes ± 0.002%(FSO)/1V
Thermal error ± 0.05%(FSO)/10ºC for range n° 1…9
± 0.08%(FSO)/10ºC for range n° 10
± 0.25%(FSO) for the whole compensation range
Special version ± 0.03%(FSO)/10ºC for range n° 1…9
± 0.1%(FSO) for the whole compensation range for range n° 1…9
Zero shift error for static pressure* ± 0.06 % (FSO)/10bar (for range n°1, 2)
± 0.01 % (FSO)/10bar (for range n°3, 4, 5, 6, 7, 9)
± 0.03 % (FSO)/10bar (for range n°8)
± 0.02 % (FSO)/10bar (for range n°10)
± 0.01 % (FSO)/10bar (for range n°2, 8 in HS version
Cut-off on radical characteristic curve up to10% of flow.
*) Zeroing in static pressure conditions with zero differential pressure eliminates this error.
5.3.5. APR-2200ALW. Metrological parameters
Accuracy ± 0.1% (FSO) for the APR-2200ALW)
The other parameters as given in the p. 5.3.4.
Sealing effect errors – as given in the relevant diaphragm seal Catalogue Card concerning the distance seal.
NOTE: The additional absolute zero error due to ambient temperature can be compensated by configuring
the transmitter, seals and capillaries in accordance with the recommendations on pages II/ 23 and
II/ 24 Product Catalogue.
5.3.6. APR-2000ALW Metrological Parameters according to PED version
APR-2000ALW transmitters which conform to PED are characterised by a measurement range of between -
1bar and 250bar, static pressure of 250bar and the overpressure of PS=275bar.
The permissible operating temperature for option according to:
- H1 Module is between TS min/max: -25ºC and 100ºC;
5.3.7. APR-2000ALW. Pressure Connectors
APR-2000ALW – C-type connector to mount together with a valve manifold see Fig.10, available for PED
version.
APR-2000ALW, with single direct diaphragm seal – as in the example (Fig.11) or with other diaphragm seals in
accordance with “DIAPHRAGM SEALS” catalogue cards.
5.3.8. APR-2200ALW, Pressure Connectors - diaphragm seals
see “DIAPHRAGM SEALS” catalogue cards.