E6 34 DTR.APC.APR.ALW.03(ENG)
5.6. APC–2000ALW/L…. Measurement ranges and metrological parameters
5.6.1. APC–2000ALW/L…level transmitter. Measurement ranges.
5.6.2. APC–2000ALW/L…level transmitter. Permitted environmental conditions
Operating temperature range -40º ÷ 85ºC
Medium temperature range -40º ÷ 40ºC
ETFE, PU+PTFE version -40º ÷ 80ºC
ETFE+PTFE version -40º ÷ 100ºC
5.6.3. APC–2000ALW/L…level transmitter. Metrological parameters.
Accuracy ± 0.16% (FSO) for the APC-2000ALW nominal range
Long term stability accuracy / 2 years
Error due to supply voltage changes ± 0.002%(FSO)/1V
Thermal error ± 0.1%(FSO)/10ºC
± 0.4%(FSO)/ in the whole compensation range.
Thermal compensation range -25…100ºC
-40…80ºC - special version
5.6.4. APC–2000ALW/L…. level transmitter. Pressure Connectors
- SG-25 sensor;
- SG-25S sensor;
- SG-25C sensor;
- SG-25S-tytan sensor;
- SG-16 sensor;
5.6.5. APC–2000ALW/L…. pressure transmitter.
Pressure range see p. 5.2.1
Metrological parameters see p. 5.6.3
Pressure connectors see p. 5.2.5
5.7. APR–2200ALW/D – Measurement ranges and metrological parameters
5.7.1. APR–2200ALW/D density transmitter. Measurement ranges
5.7.2. APR–2200ALW/D. Permitted environmental conditions
Medium temperature range -40 ÷ 80ºC
The medium must not be allowed to freeze in the immediate vicinity of the transmitter.