MEAS:CURR:AC:PHAS?
Request for phases between current and voltage in each phase.
MEAS:CURR:AC:SUM:SQ?
Request for sum of square currents.
MEAS:CURR:AC:DIST?
Request for the distortion of measured current.
MEAS:CURR:AC:TR:RAT
Transformer Test: Request for the measured transmission ratio of separate current channels (r
Lx/L1
).
MEAS:CURR:AC:TR:ERR
Transformer Test: Request for the calculated transmission error of separate current channels (er
Lx/L1
).
MEAS:CURR:AC:TR:PHAS
Transformer Test: Request for the measured phase error of separate current channels (φ
Lx/L1
).
MEAS:CURR:AC:TR:RNOM
Transformer Test: Request for the nominal transmission current ratio.
MEAS:PHAS:PRES:RANG {<range>}
Setting the range: 0 = 0-360, 1 = +-180
MEAS:PHAS:PRES:RANG?
Request for phase range.
MEAS:PHAS:PRES:DIR {<range>}
Setting the range: 0 = Clockwise, 1 = Anticlockwise
MEAS:PHAS:PRES:DIR?
Request for phase direction
MEAS:PHAS:PRES:REL {<range>}
Setting the range: 0 = Relative, 1 = Absolute
MEAS:PHAS:PRES:REL?
Request for phase relation
MEAS:POW:AC[:ACT]?
Request for active power values.
MEAS:POW:AC[:ACT]:PRIM?
Request for primary active power values.
MEAS:POW:AC:REAC?
Request for reactive power values.
MEAS:POW:AC:REAC:PRIM?
Request for primary reactive power values.
MEAS:POW:AC:APP?
Request for apparent power values.

Other manuals for Applied Precision WS 2120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Applied Precision WS 2120 and is the answer not in the manual?

Applied Precision WS 2120 Specifications

General IconGeneral
BrandApplied Precision
ModelWS 2120
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals