READ AND SAVE THESE INSTRUCTIONS
Model E100C Dehumidifier
Installation and Operating Manual
SAFETY INSTRUCTIONS
WARNING
1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
3. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.
CAUTION
1. Read all instructions before beginning installation.
2. Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.
3. Do not use in pool applications. Pool chemicals can damage the dehumidifier.
4. Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
5. Wait 24 hours before running the unit if it was not shipped or stored in the upright position
6. Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower
indoor humidity in the winter.
7. This appliance is not intended for use by persons(including children) with reduced physical, sensory, or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning the use of this appliance by a person
responsible for their safety.
8. Children should be supervised to ensure that they do not play with the appliance.
9. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
TABLE OF CONTENTS
SAFETY INSTRUCTIONS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1
SPECIFICATIONS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
REMOVE SHIPPING BRACKET � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
LOCATION CONSIDERATIONS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
LEVELING ������������������������������������������������������3
DRAIN INSTALLATION � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �4
Condensate Pump and Float Switch � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5
SETTING THE DESIRED HUMIDITY LEVEL � � � � � � � � � � � � � � � � � � � � � � � � �6
MAINTENANCE� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
Clean or Replace the Air Filter � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
Check the Drain � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �8
DUCT COLLAR INSTALLATION� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �9
Control Location� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
DUCTING � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �11
Ducting in Basement � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �11
Ducting to HVAC System in Mechanical Closet� � � � � � � � � � � � � � � � � � � 12
Ducting to Whole Home without an Air Handler� � � � � � � � � � � � � � � � � 12
TROUBLESHOOTING � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 13
Table 1 – Diagnostic Codes � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 13
Table 2 – Troubleshooting Guide � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 14
SERVICE PARTS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 15
LIMITED WARRANTY � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 16
English 1

Questions and Answers

  • B
    Brian WheelerSep 9, 2025
    Why Aprilaire E100C Dehumidifier blower is running but with little or no airflow?
    • D
      Dennis DavidsonSep 9, 2025
      If the blower in your Aprilaire Dehumidifier is running but there's little to no airflow, it could be due to a pressure drop exceeding 0.6" w.c. You should: * Check the air filter and wash or replace it. * Look for any blockages in the duct work and clear them. * Make sure the outlet collar with a backflow damper is installed on the outlet side of the dehumidifier. * Ensure the backflow damper isn't blocked or stuck; if it is, remove the obstruction.
  • E
    emartinSep 12, 2025
    What to do if Aprilaire E100C Dehumidifier blower is running but compressor is not?
    • T
      Theresa HayesSep 12, 2025
      If the blower in your Aprilaire Dehumidifier is running, but the compressor isn't, it might be due to an open float switch. If a float switch is installed, check the connections at the control board and empty the condensate pan. If there's no float switch, ensure the jumper is installed at the float switch terminals on the control board.
  • K
    Katrina PaceSep 14, 2025
    Why is my Aprilaire E100C producing hot air?
    • M
      Michael RobinsonSep 14, 2025
      The air is reheated across the condenser coil, resulting in a temperature rise between inlet and outlet of your Aprilaire Dehumidifier.
  • H
    Helen FitzgeraldSep 16, 2025
    Why does the HVAC fan turn on unexpectedly with Aprilaire E100C?
    • J
      janetwhiteSep 16, 2025
      Your Aprilaire Dehumidifier will turn on the HVAC fan during air sampling or as needed to meet the ventilation time.

Summary

Safety Instructions

Specifications

Remove Shipping Bracket

Location Considerations

Leveling

Drain Installation

Condensate Pump and Float Switch

Installation of a condensate overflow safety switch for drainage.

Setting the Desired Humidity Level

Maintenance

Clean or Replace the Air Filter

Procedure for cleaning or replacing the air filter.

Check the Drain

Annual check for drain blockages or air locks.

Duct Collar Installation

Control Location

Ducting

Ducting in Basement

How to duct the dehumidifier in a basement setup.

Ducting to HVAC System in Mechanical Closet

Installation for ducting to HVAC in a mechanical closet.

Ducting to Whole Home Without an Air Handler

Installation for ducting to a whole home without an HVAC air handler.

Troubleshooting

Diagnostic Codes

Error codes and their meanings for system faults.

Service Parts

Limited Warranty

Aprilaire E100C Specifications

General IconGeneral
BrandAprilaire
ModelE100C
CategoryDehumidifier
LanguageEnglish

Related product manuals