DUCT COLLAR INSTALLATION
HORZONTAL DISCHARGE:
• Use the screws in the parts bag to attach the duct collars to the
inlet and outlet of the dehumidifier� The outlet collar has a backflow
damper�
• The outlet duct collar may be attached to the top or end of the unit�
Move the outlet cover to the location not being used� See FIGURE7�
• Make sure there are no bends in the ductwork coming off the outlet
for a minimum of 4"� This will ensure that the ductwork will not
interfere with the backflow damper function�
VERTICAL DISCHARGE:
Use the screws provided in the parts bag to attach the duct collars:
• When the dehumidifier requires a ducted vertical discharge, remove
the top access panel and remount on the outlet of the unit� Install
the outlet duct collar with backflow damper on top of the unit� See
FIGURE7�
CONTROL LOCATION
The on-board control can be located on the top of the
dehumidifier or can be relocated to the front of the
dehumidifier if the control cannot be seen/accessed in
the top orientation� It may also be rotated 180 degrees
in either orientation as shown in FIGURE 9�
TO MOVE THE CONTROL:
1. Remove the front control panel cover�
2. Remove the filter access door and filter�
3. Detach the on-board control by removing the four
(4) screws around the control� Note: Use one hand
to support the bottom of the on-board control
when removing�
4. Keep the control in the unit and relocate to the front
access hole�
5. Secure the control with the same four screws used
to attach the control to the top of the unit�
6. Secure the control panel cover to the top of the unit�
OUTLET DUCT
DRAFT DAMPER
MOVE OUTLET
COVER AND
INSTALL OUTLET
DUCT COLLAR TO
TOP DISCHARGE
LOCATION
INLET
DUCT
COLLAR
INLET
DUCT
COLLAR
END DISCHARGE
CONTROL
CONTROL
CONTROL
PANEL COVER
90-2393
90-2017
FIGURE 7 – FULLY DUCTED INSTALLATIONS
FIGURE 8 – CONTROL LOCATION
90-2525
FIGURE 9 – CONTROL ROTATED 180 DEGREES
6