DUCTING
DUCTING IN BASEMENT
The dehumidifier can be ducted to pull air from and return dehumidified air to the HVAC return duct� This installation will ensure warm, dehumidified
air is thoroughly mixed with the HVAC system air before being discharged into the living space� Alternatively, the dehumidifier can be ducted to
discharge to the supply duct, but the external static pressure of the HVAC system must not exceed 0�7 "w�c�
REQUIRED COMPONENT:
10" Ductwork
DUCTING NOTES:
Use insulated duct when the discharge is ducted to the supply side of the HVAC system�
Use a minimum of 12" of flex duct at the dehumidifier inlet and outlet to prevent vibration noise transmission�
When ducting return to return (preferred), the dehumidifier must be wired to turn on the HVAC fan when operating�
When ducting return to supply, allow adequate space before the first branch duct to ensure the warm dehumidified air is thoroughly mixed with
the HVAC system air
HVAC/FURNACE
AIR IS PULLED
FROM AND
SUPPLIED TO THE
RETURN DUCT
10" DUCT
DEHUMIDIFIER
6 ft
MIN
AIR IS
PULLED FROM
RETURN DUCT
HVAC/FURNACE
AIR IS DISCHARGED
TO SUPPLY DUCT
10" DUCT
0.7" w.c.
MAX
90-2022 90-2023
FIGURE 10 – PREFERRED BASEMENT INSTALLATION FIGURE 11 – ALTERNATE BASEMENT INSTALLATION