AQUAERO 5 / AQUAERO 6
● Temperature sensors: All currently connected temperature sensors are auto-
matically displayed.
● Virtual sensors: Can be used to determine maximum, average or minimum
value of up to three temperature sensors each. Up to four virtual sensors
can be configured.
● Software sensors: These values can be written into the device using third
party software. They can for example be used to transmit the current CPU
temperature to the aquaero 5/6 and use this value for controlling fan
speeds. Up to eight software sensors can be configured.
● Flow sensors (Control processes can not be based on flow sensor values.)
● Power measurement: Allow calculating power dissipation from a tempera-
ture difference and corresponding flow rate. Up to four independent power
values can be calculated. (Control processes can not be based on power
values.)
● Fill level sensors (Control processes can not be based on fill level values.)
● Pressure sensors (Control processes can not be based on pressure values.)
7.2.
7.2.7.2.
7.2. Controllers
ControllersControllers
Controllers
The following controller models are available:
● Curve controllers: Adjustable control curves, defined by 16 temperature val-
ues and corresponding output values.
● Set point controllers: Automatic output adjustment to match a predefined
target temperature.
● Two point controllers: Simple on/off controller, using a lower and upper
temperature limit.
● Preset values: Constant preset values.
● RGB LED controller: Color gradient controller for the RGB LED outputs, in-
cluding temperature-dependent color gradients. (Use an USB connection
and the aquasuite software to configure these controllers.)
7.3.
7.3.7.3.
7.3. Outputs
OutputsOutputs
Outputs
The following outputs are available:
● Fans
● Power outputs
● Relay output
● LED outputs
● Pumps
8.
8.8.
8. aquasuite software
aquasuite softwareaquasuite software
aquasuite software
The Windows software aquasuite is an extensive software suite and can be used
for configuration and monitoring. The software is not required for operation
though. All configuration parameters can be saved into the device's memory.
- 16 - Aqua Computer GmbH & Co. KG © 2014-2019
Gelliehäuser Str. 1, 37130 Gleichen