28
UK
Ensure the ¾” supply connections are temporarily capped to prevent any dirt or dust ingress into
the pipe work during the making good process. Remove the caps prior to connecting the shower
valve.
Inlet pipe cover plates are available separately from Aqualisa
customer services, supplied with part no. 525301 (Midas 110),
part no. 910549 (Midas 220) or complete with the easy fit
fixing bracket (not supplied). If required, apply a thin bead of
mastic to the rear of the cover plates. Place the cover plates
onto the exposed ¾” threads flush with the finished wall surface.
Ensuring the filtered rubber inlet washers are positioned within the
valve inlets, oer the valve into position. Tighten the fixing nuts
using a suitable tool taking care not to over tighten.
We recommend the rubber filter washers should be used.
Turn on the supplies to the bath/shower mixer and turn the flow control knob on to flush the
system through. Turn o the bath/shower mixer and attach the hose, ensuring the hose washer is in
place.
If required, refer to the commissioning instructions on page 32 to adjust the maximum
temperature override button position.
Follow the Midas 110/220 adjustable height head installation on page 16 to complete the
installation.
3
4
5
6
7
IMPORTANT: We recommend to apply a suitable sealant around the connectors to
stop water entering the wall.