Arctic Cat M6000 - Troubleshooting Servomotor

Arctic Cat M6000
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
153
2. Connect the red MaxiClip and meter lead to the
black/white servo terminal; then connect the black
MaxiClip and meter lead to the yellow servo termi-
nal.
3. Rotate the servo clutch counterclockwise. The ohms
should increase as the clutch is rotated until it
reaches 4700-5000 ohms.
4. Continue the clutch rotation, and there will be a
small area in the rotation where the ohm reading will
disappear; then it will return again.
5. Continue the clutch rotation, and the ohms should
appear at a very low value but will again increase to
4700-5000 ohms. This is normal operation.
FZ088A
6. Install the servomotor.
NOTE: If the servo operates correctly and the
potentiometer test is correct but fails to operate when
connected to the ECM/regulator/rectifier at the desig-
nated RPM, see Troubleshooting Servomotor chart in
this section.

Table of Contents

Related product manuals