Service Manual
Appliance filled with flammable gas R290.
Before install and use the appliance, read the owners manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R290, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions.
Compared to common refrigerants, R290 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R290
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
Please refer to the nameplate for the charging quantity of R290.
WARNING
Appliance filled with flammable gas R290.
Appliance shall be installed, operated and stored in a room with a floor area larger
than 4 m
2
.
The appliance shall be stored in a room without continuously operating ignition sources .
(for example: open flames, an operating gas appliance or an operating electric heater.)
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
The appliance shall be stored so as to prevent mechanical damage from occurring.
Keep any required ventilation openings clear of obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
Servicing shall be performed only as recommended by the manufacturer.
Should repair be necessary, contact your nearest authorized Service Centre.
Any repairs carried out by unqualified personnel may be dangerous.
Compliance with national gas regulations shall be observed.
Read specialists manual.
24
Maintenance

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo ALICE 13 and is the answer not in the manual?

Argo ALICE 13 Specifications

General IconGeneral
Airflow115 m³/h
DisplayLED
Noise level43 dB
Product colorWhite
Built-in displayYes
Water tank capacity3 L
Suitable for room area up to15 m²
Suitable for room volume up to- m³
AC input voltage220 - 240 V
AC input frequency50 Hz
Power consumption (typical)220 W
Operating temperature (T-T)5 - 32 °C
Operating relative humidity (H-H)35 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth225 mm
Width353 mm
Height496 mm
Weight11500 g

Related product manuals