Service Manual
Technical Information
HC R290 Refrigerant Lssues
Please notice that the unit is filled with propane. Details to this refrigerant are found in chapter refrigerant. Propane is highly
flammable and leads to explosion under certain conditions. Inappropriate treatment of the unit involves the risk of severe damages
of people and material.
Basics
HC R-290 (propane) is an odourless and colourless gas of the group of hydrocarbons.
HC R-290 is heavier than air and at high concentrations can cause
narcotic effects and eventually asphyxiation.
R-290 is highly flammable within the range of 2,1% and 9,5% by volume, or 38
g/m3 to 170 g/m3 in air. The auto-ignition temperature is about 470°C.
Since R-290 is an odourless and colourless gas, it is difficult to perceive that it is
present (as with most other refrigerants).
Propane is often used as a fuel such as for heating or barbecues. However, for
use on refrigeration systems, fuel-grade propane is not suitable since it contains
high levels of impurities, which would damage the refrigeration system and may
not provide the desired refrigerating capacity or efficiency.
The structural formula of HC R-290 (propane)
I m p o r t a n t R e f r i g e r a n t P r o p e r t i e s and
Parameters:
Read More!
Guidlines for the
safe use of hydro-
carbon refrige-
rants
GIZPROKLIMA
http://www.gtz.de/
proklima
Molecular formula
C3H8
Melting point [°C]
-188
Boiling point under atmospheric pressure [°C]
-42
Molar mass [g mol -1]
44,10
Critical temperature [ °C]
96,8
Critical pressure [bar]
42
Practical limit [g/m3 ]
8
Lower flammability level LFL [g/m3 ]
38
Lower flammability level LFL [ %]
2,1
Upper flammability level UFL [ g/m3]
171
Upper flammability level UFL [ %]
9,5
Ignition temperature [ °C]
470
HC R-290 refrig-
erant has a high
grade of purity.
Propane as a
cooking gas is
not useful for
refrigeration
purpose!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo ALICE 13 and is the answer not in the manual?

Argo ALICE 13 Specifications

General IconGeneral
Airflow115 m³/h
DisplayLED
Noise level43 dB
Product colorWhite
Built-in displayYes
Water tank capacity3 L
Suitable for room area up to15 m²
Suitable for room volume up to- m³
AC input voltage220 - 240 V
AC input frequency50 Hz
Power consumption (typical)220 W
Operating temperature (T-T)5 - 32 °C
Operating relative humidity (H-H)35 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth225 mm
Width353 mm
Height496 mm
Weight11500 g