71
Armstrong International
Parc Industriel Des Hants-Sarts, 2ème Avenue No. 4, Haerstal, B-4040, Belgium
armstronginternational.com/brain
Problem: “Water leaking from DRV80...”
Check all DRV seals
Check all internal seals for wear and / or
damage. Clean and refit seals. If problem
persists, replace seals. Only use silicone
based lubricants on rubber seals in cartridge
(see page 53).
Check drain plug
Check drain plug and seal for wear and / or
damage. Make sure drain plug and seal are
fitted and tightened adequately. If problem
persists, replace both plug and seal.
Check inlet and outlet connections
Check inlet and outlet thread joints. Check a
correct seal has been made with PTFE thread
sealing tape or liquid sealant. Oil-based, non-
setting joint compounds should not be used.
DRV body failure
DRV80 replacement required.