Page #44 background imageLoading...
Page #44 background image
RDM commands
44
Manufacturer commands
Lamp Hours Shows the actual lamp hours of the fixture X
Factory Defaults This command deletes all user parameters and sets the fixture to factory default X X
Device Power Cycles Shows the power cycle value, counts every cold start (switch or power-up) X
Reset Device Fixture makes a software reset (warm start) and carries out a reboot X X
Power State
Power state of the fixture, supported power states:
POWER_STATE_STANDBY (0x02),
POWER_STATE_NORMAL (0xFF),
POWER_STATE_FULL_OFF (0x00)
POWER_STATE_SHUTDOWN (0x01)
XX
Perform Selftest Supported test modes and demo modes X X
Self Test Description Shows a description for each test / demo mode X
Command Description GET SET
RDM Fan Mode
PID: 0x8001
Changes the FAN mode of the fixture
- this message supports Set and Get commands
- the first data byte is used to show / change the fan mode
USER_FAN_MODE_LOW = 1
USER_FAN_MODE_VARI = 2
USER_FAN_MODE_HIGH = 3
XX
RDM Status LED
PID: 0x8002
Switch on /off indication LEDs and LCD back light
- this message supports Set and Get commands
- the first data byte is used to switch indication LEDs on and off
LEDs and LCD back light on = 0
LEDs and LCD back light off = 1
XX
Command Description GET SET

Other manuals for ARRI SkyPanel

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ARRI SkyPanel and is the answer not in the manual?

ARRI SkyPanel Specifications

General IconGeneral
TypeLED Soft Light
Color Temperature2800K - 10000K
CRI≥ 95
Dimming0 - 100%
ControlDMX, Ethernet
Input Voltage100-240V AC, 50/60Hz