RRM02 - Product Manual
Issue: 02 complete, approved
Page 28 of 68
Figure 19 Two RRM02 Units on One Zone Group with Chime
ROUTER
Input 1 Input 2
Contact Inputs
12
Output 1
PTT
Relay
Contact
PTT
Relay
Contact
Contact Input 1
makes a route
from
Audio Input 1 to
Audio Output 1
Contact Input 2
makes a route
from
Audio Input 2 to
Audio Output 1
Output 2
Input 3
Busy LED will not operate on the RRM02 units.
L
RS485
Busy Indication for
Audio Output 1 route
which is made from
Audio Inputs 1 or 2
Router Inputs are configured as :
y 'Miscellaneous Input'
y No chimes.
Connections:
y Audio lines only.
y No serial data connection.
Router Inputs are configured as :
y 'Miscellaneous Input'
y Chime set as required
Connections:
y Audio lines only.
y No serial data connection.
Digital Input 1 configured as
Routing Contact which
when triggered makes a
route between Audio Input 3
and Audio Output 2
BMB01
Digital
Output 1
Digital
Input 1
RRM02
Unit 2
RRM02
Unit 1

Table of Contents