EasyManua.ls Logo

Astralpool ELITE 60 - pH and ORP Sensor Calibration

Astralpool ELITE 60
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S I G N A T U R E
31
8.2.1. “FAST” MODE
“FAST” MODE allows the calibration of the pH-electrode when there are small reading deviations
with no need to extract the sensor from the installation or to use calibration solutions.
PROCEDURE:
Be sure the point of insertion of the pH-sensor is ooded, and the pump is in
recirculation.
Using a pH-test kit, measure the water pH of the swimming pool.
Press the
“CAL” [18] key for approx. 5 seconds. The pH [15] screen will blink “7.0”.
Keep the
“SET” [24] key pressed until the pH-value previously measured in the water
with the pH-test kit appears. Once reached, loosen and press “CAL” [18] key. If no
error has been detected, the system will have been calibrated.
5 seconds
8.2.2. “STANDARD” MODE
“STANDARD” MODE allows the precise calibration of the pH-sensor using two calibration
solutions of pH 7.0 and 4.0, however this method requires that the pH-sensor is removed from
the installation.
PROCEDURE:
IMPORTANT: before closing the by-pass valves, stop system from control panel as
described in section 7.7.1.
1. Extract the pH-sensor from the holder and wash it with abundant tap water.

Related product manuals