S I G N A T U R E
23
7.6.7. SYSTEM CONFIGURATION
The AstralPool Chlore Elite system can be recongured through a menu accessed from the
control panel. The system must be switched off in order to access this menu, by pressing
successively the “-” [1] key until “0%” led starts ickering. Once the system has been switched
off, press the “-” [1] key for a few seconds until the system information screen [11] displays
“CONF”. To enable selection of each menu option, keep the “SALT TEST” [9] key pressed
for approximately 1 second. Select the desired parameter using the
“-” [1] / “+” [14] keys and
validate by pressing the “SALT TEST” [9] key for one second again. The conguration process
enables you to establish the following operative parameters:
MODEL
Elite 60 Elite 100 Elite 160
SOFTWARE VERSION
Shows software version (two digits)
POLARITY SWITCH
Switch each 2 hours
(2)
Switch each 3 hours Switch each 2 minutes
(1)
OUTPUT LEVEL CONTROL
WHEN CLOSED COVER
(2)
System may be congured to provide an output to cell in the range 10 ... 90% of its
nominal capacity when the pool cover is closed.
COVER CONTROL INPUT
ACTIVATION
Deactivated
Activated input when
closed contact
(2)
Activated input when
closed contact.
ORP/RESIDUAL CHLORINE
CONTROL INPUT
ACTIVATION
Deactivated (MANUAL)
Activated electrolysis system when closed contact
(AUTO)
(2)
GAS DETECTOR
ACTIVACION
Deactivated Activated electrolysis system when ooded detector
(2)
EXTERNAL FLOW
DETECTOR
(FLOW SWITCH)
ACTIVATION
Deactivated Activated electrolysis system when closed contact
(2)
(1) WARNING: only use this mode for check tasks, for short periods of time, as it could damage the electrodes.
(2) Factory defaults.