7.6.7. SYSTEM CONFIGURATION
The AstralPool Chlore Elite system can be recongured through a menu accessed from the
control panel. The system must be switched off in order to access this menu, by pressing
successively the “-” [1] key until “0%” led starts ickering. Once the system has been switched
off, press the “-” [1] key for a few seconds until the system information screen [11] displays
“CONF”. To enable selection of each menu option, keep the “SALT TEST” [9] key pressed
for approximately 1 second. Select the desired parameter using the
“-” [1] / “+” [14] keys and
validate by pressing the “SALT TEST” [9] key for one second again. The conguration process
enables you to establish the following operative parameters:
MODEL
Elite 60 Elite 100 Elite 160
SOFTWARE VERSION
Shows software version (two digits)
POLARITY SWITCH
Switch each 2 hours
(2)
Switch each 3 hours Switch each 2 minutes
(1)
OUTPUT LEVEL CONTROL
WHEN CLOSED COVER
(2)
System may be congured to provide an output to cell in the range 10 ... 90% of its
nominal capacity when the pool cover is closed.
COVER CONTROL INPUT
ACTIVATION
Deactivated
Activated input when
closed contact
(2)
Activated input when
closed contact.
ORP/RESIDUAL CHLORINE
CONTROL INPUT
ACTIVATION
Deactivated (MANUAL)
Activated electrolysis system when closed contact
(AUTO)
(2)
GAS DETECTOR
ACTIVACION
Deactivated Activated electrolysis system when ooded detector
(2)
EXTERNAL FLOW
DETECTOR
(FLOW SWITCH)
ACTIVATION
Deactivated Activated electrolysis system when closed contact
(2)
(1) WARNING: only use this mode for check tasks, for short periods of time, as it could damage the electrodes.
(2) Factory defaults.