S I G N A T U R E
3
1.1. Table of characteristics
ELITE 60 ELITE 100 ELITE 160
Code
42353 42354 42355
Standard working voltage
230 V AC, 50 Hz.
Output (dc)
12 A 24 A 32 A
Production (g/h)
10 - 12 20 -24 25 - 32
Flow detector
Gas detector + ow switch
Salinity range / Temperature
4 – 6 g./l. / +15 – 40°C
Electrodes
SELF-CLEANING coated Titanium Estimated lifetime: 4.000 – 7.000 hours
of operation (depending on water quality)
Production control
0 – 100 % (11 production levels)
Cover control
Input for potential free contact
Programmable reduction of production from control panel when closed cover
[10 ... 90%]
Polarity switch
Programmable from control panel: 2/3 hours + test mode
External control
One input for potential free contact for external ow switch.
Programmable contact logics from unit control panel
Salt level protection
Automatic production protection
Measurement range
0.0 – 9.9 (pH) / 0 – 999 mV (ORP)
Control range
7.0 – 7.8 (pH) / 650 – 800 mV (ORP)
Precision
± 0.1 pH / ± 1 mV (ORP)
Calibration
Automatic with calibration solutions
Control outputs [pH]
One output 230 V / 500 mA for dosage pump connection
pH/ORP sensors
PPO body, range 0 – 12 (pH) / ± 2000 mV (ORP), solid electrolyte
Flow detector
PPO Noryl GFN3 Casing / paddle, stainless steel
1,4571 shaft, EPDM O-ring