TCI Library www.telephonecollectors.info
AT&T Private Pay Phone Plus February, 1988
AT&T PRIVATE PAY PHONE (ELECTRICAL & TELEPHONE WIRING
DIAGRAM)
IN THE KS-23224 SENTRY II POST
POWER CABLE (D-STATION WIRE) -
(FROM POWER TRANSFORMER)
FROM LAMP IN KS-23222
OR KS-23223 ENCLOSURES -
/-• MODULAR 2 CONDUCTOR
TELEPHONE LINE CORD
(FROM CONNECTING BLOCK)
COMPONENTS FURNISHED
WITH AT&T PRIVATE PAY PHONE
POWER TRANSFORMER
(24 V AC)
LIGHT CONTROL (FURNISHED WITH
KS-23224, LIST lL, lLC, 2L, OR 2LC POSTS)
STATION PROTECTOR
CIRCUIT
BREAKER ENCLOSURE _____ _/
(FURNISHED BY TELEPHONE COMPANY
IF REQUIRED) PROTECTOR COVER
(FURNISHED WITH KS-23224, LIST lLC OR 2LC POSTS)
ELECTRICAL GROUND LUG
CONNECTINGBLOCK-----./
(FURNISHED WITH ALL KS-23224 POSTS)
UNDERGROUND ELECTRICAL ENTRANCE (110 V AC)
(CONNECT GROUND WIRE TO GROUND LUG· 12 AWG OR LARGER)
NOT SHOWN
TELEPHONE GROUND LUG
UNDERGROUND GROUND CABLE &
TELEPHONE ENTRANCE
Figure 16 Sentry II PostfBase
Installing the Sentry II Post/Base
To get the best noise protection, orient the post in a direction so that the front opening of
the enclosure will not face an excessive noise source (streets, railroads, etc.).
To mount the post:
1. Remove Panel From Post .
Refer to Figure 1 5.
Remove the 2 security screws at the top of panel (Item 2).
Brace your knee against the right side of the post as viewed from the front (Item 2).
Place both of your hands on the opposite side of the panel (Item 2).
Pull the top and bottom of the panel simultaneously towards the right side of the
post (Item 2).