Page #37 background image
Figure 36 AL8 Gas Meter Groupings
Note: Where multiple gas meters are installed, the Responsible Person must clearly mark
each gas meter box or bracket with permanent marker (or xed and robust label) to
indicate the unit number being supplied prior to the gas connection taking place.
6.3.1 Depth and Height of Recesses
The depth and height of a recess must meet the following criteria:
Minimum depth of the recess is to be 600mm
Maximum depth of the recess is to be 1,000mm
Height of the fully sealed recess opening is to be a minimum of 2,100mm
34