1.5 Operating principle
The heat pump transmits the energy contained in the
surrounding air into the dwelling to be heated.
The heat pump consists of four main elements, in which
a refrigerant  uid (R410A) circulates.
- In the evaporator (ref. 12, gure 6, page 9) :
The energy is taken from the surrounding air and is
transmitted to the refrigerant. Because it has a low
boiling point, it changes from the liquid state to the
vapour state, even in cold weather (down to -15 °C
outdoor temperature).
- In the compressor (ref. 9, gure 6, page 9) :
The vaporised refrigerant brought to high pressure
and takes on more calories.
- In the condenser (ref. 15, gure 7) :
The energy in the refrigerant is transmitted to the
heating circuit. The refrigerant returns to liquid state.
- In the expansion valve (ref. 8, gure 6, page 9) :
The lique ed refrigerant is brought back to low pressure
and returns to its initial temperature and pressure.
The heat pump is equipped with a controller, which
controls the room temperature based on the outdoor
temperature measurement and governed by the
temperature control. The room thermostat (option)
provides a corrective action for the temperature control.
The hydraulic unit can be optionally tted with an
electrical back-up system or boiler connection which
starts up in order to provide addtional heating during
the coldest periods.
Legend :
1 - Electric box.
2 - Regulator / User interface.
3 - Start/stop switch.
4 - Hydraulic pumping unit.
5 - Distribution valve.
6 - "Gas" refrigeration connection .
7 - "Liquid" refrigeration connection.
8 - Condensation sensor.
9 - Drain valve.
10 - Safety valve.
11 - Safety thermostat.
12 - Manometer.
13 - Manual drainer.
14 - Expansion vessel.
15 - Condenser.
16 - Electrical back-ups DHW.
17 - ACI.
18 - ACI card.
Sensors :
21 - HP Initial sensor.
22 - DHW sensor.
23 - HP Return sensor.
• Regulation functions
- The heating circuit's initial temperature is controlled
by the temperature control.
- The power of the outdoor unit is modulated according
to ow heating temperature via the "inverter"
compressor.
- Control of the electrical back-up heating (option).
- The daily timer program enables you to de ne
the periods for comfortable or reduced ambient
temperature.
- Summer/winter mode switchover is automatic.
- Control of the supplementary boiler* (option).
- The room thermostat (option)*: provides a corrective
action for the temperature control.
- Control of a second heating circuit*.
- Domestic hot water: Heating time programme, control
of the operation of the DHW circulation pump.
- Managing the cooling*.
- Control of swimming pool heating*.
* If the heat pump is equipped with optional equipment and the
associated kits.
• Protection functions
- Anti-legionella cycle for domestic hot water.
- Anti-corrosion protection with titanium anode (ACI).
- Frost protection: Frost protection cuts in if the low-
temperature point of the heating circuit falls below 5 °C
(provided that the heat pump's electrical power supply
is not interrupted).
gure 7 - Hydraulic unit components
3
12
1
10
4
9
8
21
23
14
5
17
22
16
11
9
9
2
18
15
13
6 7
Installation and operating manual "1578 - EN"
Heat Pump alféa extensa duo +
- 10 -