Line Function Setting range
or display
Setting
increment
Basic
setting
Time of day and date
1 U Hours / Minutes 00:00... 23:59 1
2 U Day / Month 01.01... 31.12 1
3 U Year 1900... 2099 1
5 S Start of Summer time (Day / Month) 01.01... 31.12 1 25.03
6 S End of Summer time (Day / Month) 01.01... 31.12 1 25.10
The change of hour will appear at 3:00 rst Sunday after the regulated date.
Operator Section
20 U Language English, Français, Italiano,
Nederlands...
English
22 S Info Temporary, Permanent Temporary
26 S Operation locking On, Off Off
27 S Programming locking Off, On Off
28 I Direct setting Automatic storage,
With conrmation
With
conrmation
29 I Temperature units
Pressure units
°C, °F
bar, psi
°C
bar
70 S Display software version
Time program heating, circuit 1
500 U Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
501 U 1st phase On (start) 00:00... --:-- 10 min 6:00
502 U 1st phase Off (end) 00:00... --:-- 10 min 22:00
503 U 2nd phase On (start) 00:00... --:-- 10 min --:--
504 U 2nd phase Off (end) 00:00... --:-- 10 min --:--
505 U 3rd phase On (start) 00:00... --:-- 10 min --:--
506 U 3rd phase Off (end) 00:00... --:-- 10 min --:--
515 U Copy
516 U Default values, Circuit 1 No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
3.4.4 List of function lines (settings, diagnosis, status)
Installation and operating manual "1578 - EN" - 41 -