EasyManua.ls Logo

Atlantic alfea extensa + - 11 Maintenance of the installation; 11.1 Hydraulic checks; 12 Maintenance

Atlantic alfea extensa +
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ensure that the general electrical power supply has
been cut off before starting any repair work.
11.1 Hydraulic checks
" Warning : If frequent rells are required it is
essential that you look for any leaks.
If lling and re-pressurization are required,
check what type of uid has been used initially.
Recommended lling pressure: 1 to 2 bar (Precise
lling pressure is determined by the manometric height
of the installation).
Each year,
- Check the expansion vessel pressure (precharge 1 bar)
and the correct functioning of the safety valve.
If the installation is tted with a DHW tank:
- Verify the safety unit on the cold water supply inlet.
Make it work as prescribed by the manufacturer.
- Check the shut-off.
11.2 Checking the outdoor unit
- Dust off the heat exchanger if necessary, being careful
not to damage the ns.
- Straighten the vanes using a comb.
- Check that there is nothing obstructing the passage
of air.
- Check the fan.
- Verify that condensate drain is not obstructed.
Checking the refrigeration circuit
- When the refrigerant charge is in excess of 2kg
(models >10kW) it is compulsory to have an approved
after sales service check the refrigeration circuit every
year (with a certicate of capacity for the handling of
refrigerants) (see para. 2.1, page 13).
- Check the lack of leak (connections, valves…).
11.3 Electrical checks
- Check connections and possible tightening.
- Check the cables condition and electronic boards.
12.1 Emptying the hydraulic unit
- Remove the front panel from the hydraulic unit.
- Open the emptying valve,
- Open the hydraulic unit’s manual bleed-tap,
- Open the installation bleed tap.
12.2 Distribution valve
If the installation is tted with a DHW tank.
Carefully comply with the direction for tting the
distribution valve.
Channel AB : Inlet to the hydraulic unit .
Open channel A : Return from DHW tank.
Open channel B : Return from the heating circuit.
11 Maintenance of the installation
12 Maintenance
Installation and operation manual "1734 - EN"
Heat pump air/water split 1 service alféa extensa +
- 78 -

Table of Contents

Related product manuals