EasyManua.ls Logo

Atlantic alfea extensa + - Page 87

Atlantic alfea extensa +
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and operation manual "1734 - EN" - 87 -
Heat pump air/water split 1 service alféa extensa +
Trade name / Models : atlantic / Alféa ... extensa + 13 extensa + 16
Reference 522 226 522 227
Heating ranges 35°C 55°C 35°C 55°C
Supplementary heater
Rated heat output
(2)
P
sup
kW 1.3 1.3 1.7 2.1
Type of energy input - - Electricity
Power consumption in modes other than active mode
Off mode P
OFF
W 8 8 8 8
Thermostat-off mode P
TO
W 45 22 72 25
Standby mode P
SB
W 12 12 12 12
Crankcase heater mode P
CK
W 0 0 0 0
Other items
Capacity control
- - Inverter
For Air-to-water heat pump, rated air ow rate
- m
3
/h 6200 6200
(1) Seasonal efciency calculation is detailed in package che - room units are available as option and includes: thermostat and room sensors, room unit controller wether
they are, or not, integrated in kits.
(2) For heat pump space heaters and heat pump combination heaters, the rated heat output P
rated
is equal to the design load for heating P
designh
, and the rated heat output
of the supplementary heater P
sup
is equal to the supplementary capacity for heating sup(Tj).
(3) If Cdh is not determinated by measurement then the default degradation coefcient is Cdh=0.9.

Table of Contents

Related product manuals