Atlas Copco Elektronikon II - Status Data Menu; Shut-down Message

Atlas Copco Elektronikon II
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual
2920 1456 03 11
6 Status data menu
The status data submenu gives information regarding the status of the compressor protection
functions (shut-down, shut-down warning, service warning and warning) and allows resetting of a shut-
down, motor overload and service condition.
Procedure
Starting from the Main screen (see section 4.2):
- Press the key Menu (F1): the option Status data will be followed by a horizontal arrow.
- Press the tabulator key (2).
6.1 No message exists
In this case, LED (7) is out and the message on the display indicates that all conditions are normal
(Fig. 6.1):
All conditions
are OK
Menu
F1 F2 F3
Fig. 6.1 Example of a status data screen
6.2 A shut-down message exists
In case the compressor is shut down, LED (7) will blink.
In case of a shut-down due to too high a temperature at the compressor element outlet, a screen
similar to the one below will appear:
Element Outlet
C 122
Shd Max 120
Menu ** ** Rset
F1 F2 F3
Fig. 6.2 Example of a status data screen