User manual
2920 1456 03 15
Procedure
1. Starting from the Main screen (see section 4.2):
- press the key Menu (F1)
- press the ↓ key until the option Counters is followed by a horizontal arrow
- press the tabulator key (2) to activate the menu
2. By pressing the ↓ key, the above-mentioned items can be found (see also Fig. 4.1).
Calling up the accumulated volume:
1. Consult the section above to select the item Accumulated volume:
Accum Volume
↑
1000 m³ 230
Menu Mod
↓
F1 F2 F3
Fig. 8.1 Example of an accumulated volume screen
The display indicates that the compressor has delivered 230 x 1000 m³ of compressed air.
If it should be required to modify the value of the indicated timer, consult Atlas Copco.
9 Test menu
Function
To carry out a display test, i.e. to check whether the display and LEDs are still intact.
Procedure
1. Starting from the Main screen (see section 4.2):
- press the key Menu (F1)
- press the ↓ key until the option Test is followed by a horizontal arrow
- press the tabulator key (2) to activate the menu
2. The option Display test will be followed by a horizontal arrow.
3. After pressing the tabulator key (2), the regulator will generate a series of patterns on the display
which enable the operator to check that each pixel still functions normally; at the same time the
LEDs are lit.