EasyManua.ls Logo

Atlas Copco Elektronikon II - Page 21

Atlas Copco Elektronikon II
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual
2920 1456 03 21
Procedure
1. Starting from the Main screen (see section 4.2):
- press the key Menu (F1)
- press the key until the option Modify Params is followed by a horizontal arrow
- press the tabulator key (2) to activate the menu
2. Use the key to scroll until the option Service plan is followed by a horizontal arrow.
3. Press the tabulator key (2): a screen similar to the one below will appear:
Service Timer
Running hours
hrs 2130
Menu
F1 F2 F3
Fig. 13.1 Service plan menu
4. The screen shows the actual running hours (2130).
5. Press the tabulator key (2): a screen similar to the one below will appear:
Service Timer
Level A
hrs 4000
Menu Mod
F1 F2 F3
Fig. 13.2 Service plan menu
6. The screen indicates that the level for Service plan A is set at 4000 running hours.
7. Press the Mod key. The key Lim (F2) can be used to find out the limitations for the parameter.
Use the or arrow key to modify the interval.
8. Press the key Prog (F1) to program the new setting or the key Canc (F3) to cancel the
modification operation.
9. The procedures to modify the other Service plans (B, C, …) are carried out in a similar way.