22 Preliminary
PTS 916 Cd
When the PC mode is active, monitoring the operation on the UI
stays possible. Further, the UI can only be used for looking at the
System information and the Process information.
Control commands
Start command
Local: Pressing the Start button on the UI.
Remote: Activating the Remote Start input.
PC: Clicking the Start button on the PC.
Stop command
Local: Pressing the Stop button on the UI.
Remote: Activating the Remote Stop input.
PC: Clicking the Stop button on the PC.
Load command
Local: Pressing the Load button on the UI.
Remote: Activating the Remote Load input (when not loaded).
PC: Clicking the Load button with the mouse.
Noload command
Local: Pressing the Noload button on the UI.
Remote: Activating the Remote Load input (when loaded).
PC: Clicking the Noload button with the mouse.
Enable parameters
There are four enable parameters with four possible conditions.
The lock extension gives the Rental companies the possibility to
prohibit the operator from changing the parameters via the UI, thus
restricting the operator to one condition of the parameter.
Parameter E/D Lock CCM operation
Autostart enable x Automatic start
disable x Manual start
Autostop enable x Automatic stop
disable x Manual stop
Remote enable x Remote Control Mode
disable x Local Control Mode
Air Discharge
Temperature
Regulation
enable x Air Disch. Temp. Control activated
disable x Air Disch. Temp. Control not active
Re/Unload
Control
enable - Re/Unload press. adjustable with UI
disable - Re/Unload press. not adjustable with
UI
Unload RPM
Control
enable - Unload RPM adjustable with UI
disable - Unload RPM not adjustable with UI