32 Preliminary
PTS 916 Cd
4.4.6 Warmup status
Manual start
Other actions and signals have no effect in this status.
Automatic start
Other actions and signals have no effect in this status.
S Warnings R Are shown on the screen
A Shutdowns R To start failure status (see
section 4.4.11)
A Max. warmup time elapsed R Not Loaded status or Load/
Unload status (see section 4.4.7)
A Emergency stop button R To emergency stop status (see
section 4.4.13)
A -button, press once R Set pressure - 0.1 bar
A
-button, press once R Set pressure + 0.1 bar
A -button, press continuously R Set pressure - 0.1 bar/second
A
-button, press continuously R Set pressure + 0.1 bar/second
A Stop command R To stopping status (see section
4.4.10)
A Power OFF switch R To stopping status (see section
4.4.10)
A Auto load button
or Remote Load input
if Remote control mode
R After the Warmup status, the
CCM will skip the Not Loaded
status and go directly to the
Load/Unload status (see section
4.4.8)
“Automatic load” will appear on
the screen
If min. Warmup time is elapsed:
S Coolant = Warmup temperature R To Not Loaded status (see
section 4.4.7)
or Load/Unload status (see
section 4.4.8)
If Auto Load button was pressed:
A Manual load button
or Remote Load input
if Remote control mode
R Auto Load condition is canceled
S Warnings R Are shown on the screen
A Shutdowns R To shutdown status (see section
4.4.12)
A Max. warmup time elapsed R To Not Loaded status (see
section 4.4.7) or Load/Unload
status (see section 4.4.8)
A Emergency stop button R To emergency stop status (see
section 4.4.13)
A -button, press once R Set pressure - 0.1 bar
A
-button, press once R Set pressure + 0.1 bar
A -button, press continuously R Set pressure - 0.1 bar/second
A
-button, press continuously R Set pressure + 0.1 bar/second
A Stop command R To stopping status (see section
4.4.10)
A Power OFF switch R To stopping status (see section
4.4.10)
A Manual load button
or Remote Load input
if Remote control mode
R After the Warmup status, the
CCM will go to the Not Loaded
status (see section 4.4.7) before
going to the Load/Unload status
(see section 4.4.8)
“Automatic load” will disappear
from the display
If min. Warmup time is elapsed:
S Coolant = Warmup temp. R To Load/Unload status (see
section 4.4.8)
or Not Loaded status (see section
4.4.7)
If Manual Load button was pressed:
A Auto load button
or Remote Load input
if Remote control mode
R Manual Load condition is
canceled

Table of Contents