38 Preliminary
PTS 916 Cd
These parameters are:
Compressor status
–Engine RPM
–Set RPM
Air discharge pressure
Set pressure
LP intercooler pressure
MP intercooler pressure
Compressor oil pressure
Engine oil pressure
Engine fuel pressure
Ambient temperature
LP element temperature
MP element temperature
HP element temperature
Compressor oil temperature
Air discharge temperature
Air discharge temp. Setting
Air disch. Temp. Valve pos.
Coolant temperature
Fuel temperature
Fuel level
Engine fuel consumption
Battery voltage
Loading valve status
Engine power contact
Starter engine status
Oiler valve status
Blow-off valve status
Flap lock solenoid
Engine load
Engine boost pressure
Air inlet temperature
Other actions and signals have no effect in this status.
Other actions and signals have no effect in this status.
4.5 During operation
Regularly carry out following checks:
Check alarm lamp at the front and alarm lamp and horn at the back
of the unit.
When starting up the unit and also when a shutdown occurs, the
alarm lamps and the horn will be activated. But when a warning
occurs, only the lamps will be activated.
Check the air filter service indicator.
If the yellow signal shows in the window of the indicator (see
section 5.4.3), clean or replace the filter elements.
Check the air outlet temperature of the MP compressor element.
4.6 Stopping instructions
Close the air outlet valve(s).
On the User Interface, push the function button below the indication
Noload.
Push the Stop button.
Once the engine has stopped, switch the control panel power switch
to the OFF position.
Turn OFF the battery switch.
S Shutdowns R To Shutdown status (see section
4.4.12)
A Time-out R Back to active compressor status
A Emergency Stop button R To Emergency Stop status (see
section 4.4.13)
A -button R Scroll text down
A
-button R Scroll text up
A Return button R Back to active compressor status
A Stop command R Same function as in the active
compressor status
The pressure is not immediately relieved from the
unit, when the Stop button is pushed.
!

Table of Contents