Instruction manual
Preliminary 33
4.4.7 Not Loaded status
Other actions and signals have no effect in this status.
4.4.8 Load/Unload status
Manual stop
Other actions and signals have no effect in this status.
S Warnings R Are shown on the screen
S Shutdowns R To Shutdown status (see section
4.4.12)
A Emergency stop button R To emergency stop status (see
section 4.4.13)
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press continuously R Set pressure - 0.1 bar/second
A
↑
-button, press continuously R Set pressure + 0.1 bar/second
A Stop command R To Stopping status (see section
4.4.10)
A Power OFF switch R To Stopping status (see section
4.4.10)
A Load command R To Load/Unload status (see
section 4.4.8)
S Warnings R Are shown on the screen
A Shutdowns R To Shutdown status (see section
4.4.12)
A Emergency stop button R To emergency stop status (see
section 4.4.13)
A ↓-button, press once R Set pressure - 0.1 bar
A
↑
-button, press once R Set pressure + 0.1 bar
A ↓-button, press continuously R Set pressure - 0.1 bar/second
A
↑
-button, press continuously R Set pressure + 0.1 bar/second
A Stop command R To Cooldown status (see section
4.4.9)
A Power OFF switch R To Cooldown status (see section
4.4.9)
A Noload command R To Not Loaded status (see
section 4.4.7)
If Loaded:
S Unload pressure reached R “Unload” appears on the screen
If Unloaded:
A Reload pressure reached R “Load” appears on the screen