EasyManua.ls Logo

Atmel XMEGA A3 series

Atmel XMEGA A3 series
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
8068C–AVR–06/08
XMEGA A3
22. IRCOM - IR Communication Module
22.1 Features
Pulse modulation/demodulation for infrared communication
Compatible to IrDA 1.4 physical for baud rates up to 115.2 kbps
Selectable pulse modulation scheme
3/16 of baud rate period
Fixed pulse period, 8-bit programmable
Pulse modulation disabled
Built in filtering
Can be connected to and used by one USART at the time
22.2 Overview
XMEGA contains an Infrared Communication Module (IRCOM) for IrDA communication with
baud rates up to 115.2 kbps. This supports three modulation schemes: 3/16 of baud rate period,
fixed programmable pulse time based on the Peripheral Clock speed, or pulse modulation dis-
abled. There is one IRCOM available which can be connected to any USART to enable infrared
pulse coding/decoding for that USART.

Table of Contents

Related product manuals