Page #41 background imageLoading...
Page #41 background image
Mediant 800C with ZPLS
- 35 -
To configure an IP Profile for the Generic SIP Trunk:
1. Open the IP Profiles table (Setup menu > Signaling & Media tab > Coders & Profiles folder >
IP Profiles).
2. Click +New add the IP Profile for the Generic SIP Trunk. Configure the parameters using the
table below as reference.
Table 11: Configuration Example: Generic SIP Trunk IP Profile
Parameter
Value
General
Index
2
Name
SIPTrunk
Media Security
SBC Media Security Mode
Not Secured
SBC Media
Extension Coders Group
AudioCodersGroups_2
Allowed Audio Coders
SIPTrunk Allowed Coders
Allowed Coders Mode
Restriction and Preference (reorder coders according to
Allowed Coders including extension coders)
SBC Signaling
P-Asserted-Identity Header Mode
Add (required for anonymous calls)
3. Click Apply.