NOTICE for use!
This document is only valid with the latest operation instructions attached to the device, the attached manual as
well as the respectively pertaining technical and electrical data sheets.They are understood as reference
documents.
Purpose of the document:
The present document informs about the actions required for using the device in safety-related systems in
accordance with IEC 61508 or IEC 61511.
The safety manual is primarily intended for consultants, operators, service staff and managers setting up, operating
or maintaining safety instrumented systems (SIS) equipped with FQM / FQMEx fail safe unit. Together with the
reference documents, the present safety manual provides all information required for safe SIS integration,
operation and maintenance of the FQM / FQMEx fail safe unit.
Reference documents:
●
Operation instructions (Assembly, operation, commissioning) for actuator.
●
Operation instructions (Assembly, operation, commissioning) Fail safe unit.
●
Manual (Operation and setting) AC 01.2/ACExC 01.2 actuator controls.
●
Manual (Device integration Fieldbus) AC 01.2/ACExC 01.2 actuator controls.
●
Technical data referring to the fail safe unit, the actuator and actuator controls.
●
Declaration of incorporation and EU declaration of conformity for the fail safe unit.
●
SIL Declaration of Conformity on functional safety (order related)
Reference documents are available on the Internet at: http:\\www.auma.com.
Table of contents Page
41. Terminology............................................................................................................................
41.1. Abbreviations and concepts
62. Application and validity.........................................................................................................
62.1. Range of application
62.2. Standards
62.3. Valid device types
83. Architecture, configuration and applications......................................................................
83.1. Architecture (actuator sizing)
83.2. Configuration (setting)/version
103.3. Further notes and indications on architecture
103.4. Applications (environmental conditions)
114. Safety instrumented system and safety functions.............................................................
114.1. Safety instrumented system including an actuator
114.2. Safety functions
124.3. Safe inputs and outputs
134.4. Redundant system architecture
144.5. Application example
144.6. System representation
144.7. Diagnostic function by the operator
154.8. Internal diagnostics of fail safe unit
165. Installation, commissioning and operation.........................................................................
165.1. Installation
185.2. Commissioning
2
Table of contents with non safety-related actuators