SG 05.1 SG 12.1/SGR 05.1 SGR 12.1
Control unit: electronic (MWG)
with actuator controls
AUMATIC AC 01.1 Non-Intrusive
Assembly, operation, commissioningOperation instructions

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AUMA SG 05.1 and is the answer not in the manual?

AUMA SG 05.1 Specifications

General IconGeneral
BrandAUMA
ModelSG 05.1
CategoryController
LanguageEnglish

Summary

Safety Instructions

Basic Information on Safety

General safety rules, standards, personnel qualifications, commissioning, and operation guidelines.

Range of Application

Defines intended use for industrial valves and lists prohibited applications.

Applications in Ex Zone 22 (Option)

Requirements for dust hazardous locations (Zone 22) and ATEX directive compliance.

Warnings and Notes

Explains signal words (DANGER, WARNING, CAUTION, NOTICE) and their risk levels.

Assembly

Electrical Connection

Basic Information

General warnings and information regarding electrical connections and protection.

Connection with AUMA Plug/Socket Connector

Instructions for connecting using the AUMA plug/socket connector.

Operation

Manual Operation

How to operate the actuator manually for setting and commissioning.

Local Operation

How to operate the actuator using the local control push buttons.

Operation from REMOTE

How to operate the actuator remotely via fieldbus.

Indications

Status Indications in the Display

Explains how status indications in the display show operation states, faults, and warnings.

Signals

Commissioning (Basic Settings)

End Stop CLOSED: Set

Step-by-step instructions for setting the CLOSED end stop.

End Stop OPEN: Set

Step-by-step instructions for setting the OPEN end stop.

Type of Seating: Check/Edit for End Positions

How to check and edit seating modes (LIMIT, OPEN, CLOSED) for end positions.

Torque Switching: Check/Set

How to check and set torque switching for overload protection.

Limit Switching: Set

Steps to set limit switching for OPEN and CLOSED end positions.

Baud Rate, Parity and Bus Address (Slave Address): Set

How to set Modbus interface parameters like baud rate, parity, and slave address.

Direction of Rotation: Check

How to check the direction of rotation and precautions to avoid valve damage.

Limit Switching: Check

How to check if the limit switching is set correctly.

Corrective Action

Faults during Commissioning

Common faults during commissioning and their remedies.

Fault Indications and Warning Indications

Explains fault and warning indications shown in the display.

Status Indication S0 - Faults and Warnings

Details how S0 displays faults and warnings and lists signal descriptions.

Status Indication S1 - Faults

Describes fault indications within status indication S1 and their remedies.

Motor Protection (Thermal Monitoring)

Explains motor protection via PTC thermistors/thermoswitches and associated signals.

Servicing and Maintenance

Technical Data

Features and Functions of Actuator

Lists key features and functions of the part-turn actuators.

Features and Functions of Actuator Controls

Lists key features and functions of the AUMATIC actuator controls.

Modbus Interface

Details settings, commands, signals, and general data for the Modbus interface.