EasyManuals Logo

AUMA SA Series Manual

AUMA SA Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
217.3. Status signals via output contacts (digital outputs) of standard controls
217.4. Signal via fieldbus of standard controls
238. Tests and maintenance..........................................................................................................
238.1. Safety equipment: check
238.2. Internal actuator monitoring with control via standard controls
238.3. Partial Valve Stroke Test (PVST): execute
248.4. Proof test (verification of safe actuator function)
258.4.1. Safe ESD safety operation (Safe OPENING/CLOSING)
268.4.2. SIL fault signal "Actuator monitoring": check
268.4.3. Safe ESD reaction for "Motor protection (thermal fault)" signals: check
278.4.4. Safe ESD reaction to "Limit seating with overload protection" (limit and/or torque eval-
uation): check
298.4.5. Safe ESD reaction to "Forced limit seating in end position" (limit evaluation) for actu-
ators with electromechanical control unit: check
298.4.6. Safe ESD reaction for "Forced limit seating in end position" (limit evaluation) for actu-
ators with electronic control unit and limit switches: check
308.4.7. Safe ESD reaction to "Forced torque seating in end position" (torque after limit evalu-
ation): check
318.4.8. Safe ESD reaction for "No seating" (no evaluation of limit and torque): check
328.4.9. Safe STOP function: check
338.4.10. Combination of Safe ESD and Safe STOP function: check
348.5. Maintenance
359. Safety-related figures.............................................................................................................
359.1. Determination of the figures
369.2. Specific figures for AC 01.2 controls in SIL version with actuators of SA.2 series
3910. SIL Certificate.........................................................................................................................
4011. Checklists...............................................................................................................................
4011.1. Commissioning checklist
4011.2. Proof test checklists
4011.2.1. Safe ESD safety operation (Safe OPENING/CLOSING)
4011.2.2. SIL fault signal "Actuator monitoring"
4111.2.3. Safe ESD reaction to "Motor protection (thermal fault)" signals
4211.2.4. Safe ESD reaction to "Limit seating with overload protection" (limit and/or torque eval-
uation)
4211.2.5. Safe ESD reaction to "Forced limit seating in end position" (limit evaluation) for actu-
ators with electromechanical control unit
4311.2.6. Safe ESD reaction to "Forced limit seating in end position" (limit evaluation) for actu-
ators with electronic control unit and limit switches
4411.2.7. Safe ESD reaction to "Forced torque seating in end position" (torque after limit evalu-
ation)
4411.2.8. Safe ESD reaction to "No seating"
4511.2.9. Safe STOP function
4611.2.10. Combination of Safe ESD and Safe STOP
49Index........................................................................................................................................
50Addresses...............................................................................................................................
3
Multi-turn actuators
SA 07.2 SA 16.2/SAR 07.2 SAR 16.2 Table of contents

Table of Contents

Other manuals for AUMA SA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SA Series and is the answer not in the manual?

AUMA SA Series Specifications

General IconGeneral
Torque range10 Nm to 32, 000 Nm
Protection classIP68
Ambient temperature+70°C
Voltage24V DC
CommunicationPROFIBUS DP, MODBUS RTU, Foundation Fieldbus
CertificationsATEX, IECEx, CSA, GOST, SIL
ControlLocal, Remote, Bus (PROFIBUS, MODBUS)

Related product manuals