6.4.4. Terminal compartment: close
Figure 34: Close terminal compartment
[1] Cover (figure shows KP version)
[2] Screws for cover
[3] O-ring
[4] Blanking plugs
[5] Cable gland
[6] Flameproof frame
1. Clean sealing faces of cover [1] and frame [6].
2. Check whether O-ring [3] is in good condition, replace if damaged.
3. Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
4. Fit cover [1] and fasten screws [2] evenly crosswise.
5. Fasten cable glands and blanking plugs applying the specified torque to ensure
the required enclosure protection.
37