Signals Possible reason Solutions
The red LED blinks
twice per second during
start up.
At least one of the
pushbuttons is pressed or
damaged.
Bring the pushbuttons to the rest
position.
The red LED blinks
three times per second
during start up.
The battery is at. Replace the battery with a charged one.
The red LED is steady
on for two seconds
during start up.
The Transmitting Unit
does not work correctly.
Contact the support service of the
Machine Manufacturer.
The green and red LEDs
are steady on during
start up.
A wrong "ID internal
tx memory" has
been inserted in the
Transmitting Unit.
Use the correct "ID internal tx memory".
You're using a "BACK-
UP UNIT" with the "ID
internal tx memory" of the
Transmitting Unit that has
been replaced.
Store the address in the "BACK-UP
UNIT" (see paragraph 8.13).
The green and red LEDs
blink three times per
second during start up.
"ID internal tx memory" is
damaged.
Contact the support service of the
Machine Manufacturer.
The green LED is lit
with a steady light and
the red LED blinks two
times per second during
start up.
The START pushbutton is
activated.
release the START pushbutton.
The green LED repeats
the sequence: 3 blinks
and a pause, and the
red LED is steady on
during start up.
The UNPAIR procedure
provided in the document
"Menu of Transmitting
Unit (MTU)" has been
carried out.
If the Transmitting Unit has an "ID
internal tx memory", perform the
ALIGNMENT procedure.
If the Transmitting Unit does not have
an "ID internal tx memory", perform the
PAIR procedure.
12 Decommissioning and disposal
Instructions for correct decommissioning and disposal of Radio Remote Controls are described
in chapter "Decommissioning and disposal" in "Part A" of the Instruction Manual. Therefore,
please refer to that part of the Manual.
AUTEC - Air series
Decommissioning and disposal 33
LIUA8BEN0_eng-01