31
Figure 4-19 Waveform Edit Screen
Digital Gauge Mode — displays the parameters in the form of a digital gauge
graph.
Trigger Settings
On the Trigger Settings screen, you can set a standard range by filling in a minimum
value and a maximum value. When exceeding this range, the trigger function will be
executed and the tablet will automatically record and save the generated data. You can
review the saved live data by tapping the Review button at the bottom of the screen.
Tap the drop-down button on the right side of a parameter to open a submenu. The
Trigger button is the last one in the submenu. Tap to display the Trigger Settings screen.
Figure 4-20 Trigger Setting Screen