Automatic Systems Logic D1 v06-02-en0802.doc ERB-PM Technical manual
4/31
1.2.
Technical specifications
Power tensions: 110V – 120V – 130V – 220V –230V (default) – 240V
Power consumption: 12VA
Frequency: 50/60Hz
Ambient air temperature: -20°C - +50°C
Maximal power of the motor: 370W
24V inputs consumption: 10mA
Available power to the AS1200 board 150mA under 24V DC
1.3.
Abbreviations used
AS Link Connector for the programming console
BLQF Blocked close command
BLQO Blocked open command
BP Push button
DP Presence sensor (for example a presence detector or a photocell)
LED Light Emitting Diode
EEPROM Electrically Erasable Programmable Read Only Memory
FC Limit switch
FCF Closing Limit Switch
FCL Boom presence switch in the electromechanical tip support
FCM Crank safety switch
FCO Opening Limit Switch
FCV Lock limit switch on the electromechanical tip support
FRB Barrier closing
HS Out of order
I²C bus Inter-Integrated Circuit Bus: internal interconnection collector
I/O Input/Output
OVB Barrier opening
RS232 Serial communication
STOP Stop command (stops the movement)
1.4.
References
Electrical technical file: BLR-D-E01-H03-S05-R00-dte.doc