C2-2040(HS)-GigE Camera Hardware Reference Manual Rev. 1.8 35
Alternate Method for Configuring Multi Slope Mode (Deprecated)
The Multiple Slope mode can be also configured using Genicam registers of the SensorControl. This
alternate method is deprecated and it exists only due to compatibility reasons with older firmware
revisions:
Single Slope Mode (default mode)
1
3
2
1
3
2
1
3
2
Dual Slope Mode
1
3
2
1
3
2
1
3
2
Triple Slope Mode
1
3
2
1
3
2
Integration
time
Intensity
Satura tion
1
3
2
Integration
time
Intensity
Satura tion
1
3
2
Integration Integration
Time
Intensity
DS
Time
3
Saturation
1
2
DS Slope
Time
Vlow2
3
1
2
64
127
Integration
Time
3
1
2
Integration
Intensity
3
1
2
DS
Time
DS Slope
Time
TS
Time
Slope
Time
Vlow3
Vlow2
Saturation
64
127
The MultipleSlope parameters Vlow2 and
Vlow3 can be adjusted in the range of 127
(zero intensity) down to 64 (saturation).