Autronica AutroGuard V-530 - User Manual

Autronica AutroGuard V-530
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
utronica Fire And Security AS

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Autronica AutroGuard V-530 and is the answer not in the manual?

Autronica AutroGuard V-530 Specifications

General IconGeneral
CategorySecurity Sensors
TypeFlame Detector
Field of View90 degrees
Operating Temperature-40°C to +70°C
Humidity0 to 95% RH, non-condensing
IP RatingIP66
Power Supply24 VDC
OutputRelay and 4-20 mA
MaterialStainless Steel
CertificationsATEX, IECEx, FM

Summary

Safety Information and Regulations

Important Safety Information

Highlights critical safety warnings, warranty disclaimers, and liability limitations.

Intended Use of the Protector

Specifies the protector's intended application within Autronica fire detection systems.

Mounting, Installation, Commissioning, and Maintenance

Provides guidelines for safe installation, operation, and maintenance of products.

Modifications to the Products

States that product modifications are not allowed and disclaims liability for changes.

Protector Overview and Variants

Series and Variants

Details the different AutroGuard protector series and variants available.

Details for Ordering

Provides information and matrices for ordering AutroGuard V-430 and V-530 variants.

Technical Specifications of AutroGuard Protectors

Protector and Base Specifications

Details dimensions, materials, ingress protection, and current consumption.

Integrated Sounder Specifications

Covers sound pressure levels, current consumption, and sound patterns.

Integrated VAD Specifications

Details VAD intensity settings, current consumption for white and red LEDs.

Functional Description of Protectors

DYFI3 D - Particle;Smoke Signature Analysis

Describes the DYFI3D technology for analyzing smoke signatures.

DYFI3 D - Dynamic Filtering

Explains the dynamic filtering functions (smouldering, transient, pollution) for false alarm reduction.

Sensitivity Classes for Environmental Adaptivity

Details sensitivity classes (High, Medium, Low) for adapting to different environments.

SelfVerify 2.0 Function

Explains the automatic self-test function for sensor verification and system integrity.

Visual Alarm Device (VAD) Information

VAD Intensity Settings

Covers factors for selecting VAD intensity and configuration options (High, Medium, Low, Open).

Planning for Protector Installation

Reference to National;Local Regulations

Stresses the importance of adhering to local regulations for installation.

Environmental Requirements and Location

Outlines requirements for location, required space, and mounting considerations.

Area Coverage and Monitoring Distance

Provides guidance on area coverage and monitoring distance for smoke and heat detection.

Mounting Instructions for Protectors

Connecting Loop Cables

Explains cable requirements, wire routing, stripping, and connection methods.

Configuration of AutroGuard Protectors

Site Configuration System Settings

Details how to access and configure system settings, including detector defaults.

AutroGuard Default Settings

Guides on setting default properties for different protector variants and add-ons.

AutroGuard Individual Settings

Covers individual settings for Fire Alarm Devices, Automatic Test Mode, and Cover Detection.

Testing and Maintenance Procedures

SelfVerify 2.0 Function for Testing

Recommends using the SelfVerify® 2.0 function for automated protector tests.

Manual Testing Procedures

Outlines manual testing procedures and recommended test equipment (Testifier®).

Replacing a Protector (Hot Swap)

Details the process for replacing protectors during normal operation without system breaks.